Jun Dai & Michael M. Ohadi 
Optimum Cooling of Data Centers [PDF ebook] 
Application of Risk Assessment and Mitigation Techniques

Support

This book describes the use of free air cooling to improve the efficiency of, and cooling of, equipment for use in telecom infrastructures. Discussed at length is the cooling of communication installation rooms such as data centers or base stations, and this is intended as a valuable tool for the people designing and manufacturing key parts of communication networks. This book provides an introduction to current cooling methods used for energy reduction, and also compares present cooling methods in use in the field. The qualification methods and standard reliability assessments are reviewed, and their inability to assess the risks of free air cooling is discussed. The method of identifying the risks associated with free air cooling on equipment performance and reliability is introduced. A novel method of assessment for free air cooling is also proposed that utilizes prognostics and health management (PHM).

This book also:

Describes how the implementation of free air cooling can save energy for cooling within the telecommunications infrastructure.

Analyzes the potential risks and failures of mechanisms possible in the implementation of free air cooling, which benefits manufacturers and equipment designers.

Presents prognostics-based assessments to identify and mitigate the risks of telecommunications equipment under free air cooling conditions, which can provide the early warning of equipment failures at operation stage without disturbing the data centers’ service.

Optimum Cooling for Data Centers is an ideal book for researchers and engineers interested in designing and manufacturing equipment for use in telecom infrastructures.

€96.29
payment methods

Table of Content

Overview of Telecom Industry and Data Centers.- Cooling Methods to Improve Energy Efficiency in Telecom Industry and Data Centers.- Free Air Cooling.- Standards for Telecom Equipment and Data Centers.- Risks of Free Air Cooling.- Steps to Assess Parts for use under Free Air Cooling Condition.- Guidelines for Part Reliability Assessment.- Introduction to PHM.- Development of Sub-system and System for Free Air Cooling.- Future Trends.

Buy this ebook and get 1 more FREE!
Language English ● Format PDF ● Pages 186 ● ISBN 9781461456025 ● File size 5.8 MB ● Publisher Springer New York ● City NY ● Country US ● Published 2013 ● Downloadable 24 months ● Currency EUR ● ID 2854506 ● Copy protection Social DRM

More ebooks from the same author(s) / Editor

11,252 Ebooks in this category